Sensors with voltage output - 3 years warranty
Sensors for measuring temperature, relative humidity, CO2, atmospheric pressure and other quantities with voltage output.
Sensors with voltage output can be used for temperature monitoring in production processes, industry, food industry or healthcare. However, not only temperature but also relative humidity, atmospheric pressure or CO2 can be measured. The sensors usually have an output of 0 to 10 V and can be further processed and stored in the control panel via a wire line.
The sensors are available in various IP-protected versions with internal and external sensors that can measure temperatures even in extreme ranges.

Comet P4211 temperature transmitter with 0-10V output
In stock
78,79 €
excl. VAT
95,34 € incl. VAT
| Temperature range (max) | 600 °C, závisí na typu připojené sondy |
|---|---|
| Temperature range (min) | -200 °C, závisí na typu připojené sondy |
The Comet T4211 transmitter is designed for temperature measurement using an external temperature probe with a Pt1000 sensor. The maximum…


Comet T0213D temperature and humidity sensor with 0-10V output
In stock
234,71 €
excl. VAT
284 € incl. VAT
| Temperature range (max) | 125 °C |
|---|---|
| Temperature range (min) | -30 °C |
| Humidity measurement range | 0 to100% |
The Comet T0213D sensor is designed to measure temperature and relative humidity in the air duct using a built-in sensor, the length of the…

Comet T0213 temperature and humidity sensor with 0-10V output
In stock
234,71 €
excl. VAT
284 € incl. VAT
| Temperature range (max) | 125 °C |
|---|---|
| Temperature range (min) | -30 °C |
| Humidity measurement range | 0 to100% |
The Comet T0213 sensor is designed to measure temperature and relative humidity in the air duct using a built-in sensor, the length of the…

Comet T4211 temperature transmitter with 0-10V output
In stock
106,69 €
excl. VAT
129,09 € incl. VAT
| Temperature range (max) | 600 °C, závisí na typu připojené sondy |
|---|---|
| Temperature range (min) | -200 °C, závisí na typu připojené sondy |
The Comet T4211 transmitter is designed for temperature measurement using an external temperature probe with a Pt1000 sensor. The maximum…

Interior temperature sensor Comet T0218 with 0-10V output
In stock
120,64 €
excl. VAT
145,97 € incl. VAT
| Temperature range (max) | 50 °C |
|---|---|
| Temperature range (min) | -10 °C |
The Comet T0218 indoor temperature sensor is designed for measuring indoor temperature and for building energy management. The design of…

Comet T3218 indoor temperature and humidity sensor with 0-10V output
In stock
178,09 €
excl. VAT
215,49 € incl. VAT
| Temperature range (max) | 50 °C |
|---|---|
| Temperature range (min) | -10 °C |
| Humidity measurement range | 5 to 95 % |
The Comet T3218 indoor sensor is designed for measuring indoor temperature and relative humidity and for energy management in buildings. It…

Interior atmospheric pressure sensor Comet T2218 with 0-10V output
In stock
201,07 €
excl. VAT
243,29 € incl. VAT
The Comet T2218 indoor atmospheric pressure sensor is designed to measure the pressure inside buildings. The display and output of pressure…


Comet T0211 temperature and humidity sensor with 0-10V output
usually in stock
from
240,87 €
excl. VAT
from 291,45 € incl. VAT
| Temperature range (max) | 105 °C |
|---|---|
| Temperature range (min) | -30 °C |
| Humidity measurement range | 0 to100% |
The Comet T0211 sensor is designed to measure temperature and relative humidity using an external probe. The instrument comes standard with…

Comet T0210 temperature and humidity sensor with 0-10V output
Immediately in stock
222,81 €
excl. VAT
269,60 € incl. VAT
| Temperature range (max) | 80 °C |
|---|---|
| Temperature range (min) | -30 °C |
| Humidity measurement range | 0 to100% |
The Comet T0210 is designed to measure room temperature and relative humidity outside or inside using a built-in sensor. It can also…

Comet P0210 temperature sensor with 0-10V output
Upon request
88,63 €
excl. VAT
107,24 € incl. VAT
| Temperature range (max) | 80 °C |
|---|---|
| Temperature range (min) | -30 °C |
The Comet P0210 sensor is designed to measure indoor and outdoor temperature using a built-in sensor with IP65 protection. The device is…

Comet T5240 CO2 sensor with 0-10V output
Upon request
297,09 €
excl. VAT
359,48 € incl. VAT
| CO2 measurement range | 2000 ppm |
|---|
The Comet T5240 sensor is designed to measure the concentration of carbon dioxide CO2 using a built-in sensor. The CO2 measurement is based…


Comet T5241 CO2 sensor with external probe and 0-10V output
Upon request
738,61 €
excl. VAT
893,72 € incl. VAT
| CO2 measurement range | 10000 ppm |
|---|
The Comet T5241 sensor is designed to measure CO2 concentration using an external probe on a cable. The CO2 measurement is based on the…


Comet T5245 CO2 sensor for air duct with 0-10V output
Upon request
313,09 €
excl. VAT
378,84 € incl. VAT
| CO2 measurement range | 2000 ppm |
|---|
The Comet T5245 sensor is designed to measure CO2 concentration in the air duct, stem length 130mm. CO2 measurement is based on the NDIR…

Comet T8248 indoor CO2 and temperature sensor with 0-10V outputs
Upon request
320,07 €
excl. VAT
387,28 € incl. VAT
| Temperature range (max) | 50 °C |
|---|---|
| Temperature range (min) | -10 °C |
| CO2 measurement range | 2000 ppm |
The Comet T8248 indoor sensor is designed to measure CO2 concentration and temperature indoors and for energy management in buildings. The…


Comet P0212 air duct temperature sensor with 0-10V output
Upon request
113,66 €
excl. VAT
137,53 € incl. VAT
| Temperature range (max) | 80 °C |
|---|---|
| Temperature range (min) | -30 °C |
The Comet P0212 sensor is designed to measure the temperature in the air duct using a built-in sensor, the length of the stainless steel…


Temperature and humidity sensor Comet T0211P with probe up to 25bar pressure and 0-10V output
In stock
from
357 €
excl. VAT
from 431,97 € incl. VAT
| Temperature range (max) | 105 °C |
|---|---|
| Temperature range (min) | -30 °C |
| Humidity measurement range | 0 to100% |
The Comet T0211P sensor is designed to measure temperature and relative humidity of pressurized air up to 25 bar using an external probe…