The Comet MS6D monitoring panel offers measurement of temperature, humidity, pressure, CO2, voltage, current, pulse and other variables. It offers sixteen input connectors for connecting external wired probes and sensors. It offers the greatest variation and combination of ways to monitor the environment. Accessories include a wide range of sensors and sensing devices that can be used for this control panel. Selected sensors can be calibrated and a calibration certificate issued. Alternatively, a complete validation of the entire system can be carried out. More
The Comet MS6D monitoring panel offers measurement of temperature, humidity, pressure, CO2, voltage, current, pulse and other variables. It offers sixteen input connectors for connecting external wired probes and sensors. It offers the greatest variation and combination of ways to monitor the environment. Accessories include a wide range of sensors and sensing devices that can be used for this control panel. Selected sensors can be calibrated and a calibration certificate issued. Alternatively, a complete validation of the entire system can be carried out. More
make an autonomous time record of the measured quantities
create alarm conditions
to perform other actions based on the alarms generated (acoustic, optical signalling, control of relay outputs, sending SMS messages, control of the telephone annunciator, transmission of messages using various Ethernet interface protocols, etc.)
on-line monitoring of measured values and statuses
independent setting of hysteresis, delay (for each channel separately)
setting up to four alarm conditions (for each channel separately)
General connection options:
The MS recording system can be configured for almost any input signal. Sensors can be connected to the MS control panel in a star, in series, or a combination of both. The MS monitoring system features a wide range of communication interfaces such as RS232, RS485, USB, Ethernet and GSM or GPRS modem. Using Wi-Fi routers, several measuring panels can be connected wirelessly to a single network.
MS6xx programmable inputs and ranges
The MS6D control panel is equipped with 16 freely programmable universal inputs. Each can be set to an input signal as shown in the table below. This makes the control panel very flexible and offers ease of use. The RS485 input must be ordered separately if you want to use the Modbus or Advantech communication interface.
Description of features:
Software-configurable inputs for Pt and Ni temperature sensors, thermocouples and thermistors, voltage and current, two-state events, sensors with RS485 output.
memory for 500,000 records with automatic download to PC
Alarm indication via integrated acoustic element, e-mail and SMS
PC data analysis software
communication interfaces USB, RS232, relay, RS485 (Modbus RTU) and Ethernet (Modbus TCP, SOAP and others)
The text was translated by an automatic translator.