Comet P-line digital temperature and humidity probe with a cable of different lengths that can be selected in the configuration. The cable is terminated with a CINCH connector for connection to the Comet P8xx1 series of Web sensors. The probe offers temperature measurement from 0 to +50°C and relative humidity from 10 to 90% RH. The probe has a diameter of 18 mm and the probe body itself is 69 mm long. If you wish, we can calibrate the probe and issue a calibration certificate. However, a display unit must be supplied or purchased with the probe. More
Product code: COM-DSRH01-5+ Shipping and Payment
from 105,05 € excl. VAT (127,11 € incl. VAT)
Specify product selection
Variant does not exist
No calibration Calibration of the logger for refrigerators +2°C/+4°C/+8°C Logger calibration for medicine storage 0°C/+15°C/+25°C Logger calibration at room temperature +10°C/+20°C/+30°C Logger humidity calibration 50%/60%/70% Temperature and humidity logger calibration +10°C/+20°C/+30°C, 50%/60%/70% Temperature and humidity calibration of the logger - own calibration points Logger temperature calibration - own 3 calibration points Logger humidity calibration - own 3 calibration points

Comet P-line digital temperature and humidity probe with a cable of different lengths that can be selected in the configuration. The cable is terminated with a CINCH connector for connection to the Comet P8xx1 series of Web sensors. The probe offers temperature measurement from 0 to +50°C and relative humidity from 10 to 90% RH. The probe has a diameter of 18 mm and the probe body itself is 69 mm long. If you wish, we can calibrate the probe and issue a calibration certificate. However, a display unit must be supplied or purchased with the probe. More
Product code: COM-DSRH01-5+ Shipping and Payment
The text was translated by an automatic translator.
Parameters
Temperature range (max) 50 °C
Temperature range (min) 0 °C
Temperature measurement accuracy ± 0,5 °C
Humidity measurement range 10 to 90%
Humidity measurement accuracy ±3.5% RH (10% – 90% RH) při 25°C
Probe cable length 1 m, 2 m, 5 m
Connectors for sensors CINCH
cover IP40
In this section, you will find answers to frequently asked questions regarding use, measurement accuracy, verification, and calibration. If you cannot find the information you are looking for here, please do not hesitate to contact us—we will be happy to provide you with details based on how you use the measuring device. Telefon: +420 771 230 755 E-mail: kalist@kalist.cz