Temperature, humidity, pressure data logger LOG40 for external probes

Temperature, humidity, pressure data logger LOG40 for external probes


TFA The simple data logger TFA 31.1065.02 - LOG40 offers the connection of an external temperature, humidity and barometric pressure probe. The datalogger records in the internal memory, and the measured values ​​can be easily downloaded to Excel or a report using USB. More
Product code: TFA31.1065.02 Shipping and Payment
67,83 € excl. VAT (82,07 € incl. VAT)
Specify product selection
No calibration Calibration for refrigerators +2°C/+4°C/+8°C Calibration for drug storage 0°C/+15°C/+25°C Calibration at room temperature +10°C/+20°C/+30°C Temperature calibration - own 3 calibration points
Immediately in stock - up to 10 pieces
TFA The simple data logger TFA 31.1065.02 - LOG40 offers the connection of an external temperature, humidity and barometric pressure probe. The datalogger records in the internal memory, and the measured values ​​can be easily downloaded to Excel or a report using USB. More
Product code: TFA31.1065.02 Shipping and Payment

Accessories3

The LOG40 datalogger records temperatures, relative humidity or barometric pressure using external probes (not included in the package). It is suitable for refrigerators, warehouses with medical devices, but also for server rooms and other applications. The internal memory for 40,000 values ​​stores the measured data. After connecting to a computer, the datalogger will generate a PDF report with a preset recording interval. It is factory set to 15 minutes, but it is possible to set the data logger to record from one second to 24 hours. The device can sound an alarm when the set values ​​are exceeded. The integrated motion detector records vibrations. It is therefore possible to evaluate when the device was manipulated. It is ideal for placing on the refrigerator door, when every time it is opened it is recorded in the memory. In case of exceeding the temperature in the refrigerator, it is then possible to document historically when the door was manipulated.

Parameters
Temperature range (max) 60 °C
Temperature range (min) -40 °C
Temperature resolution 0,1 °C
power supply 2x 1,5V AAA baterie (součástí balení)
cover IP65
In this section, you will find answers to frequently asked questions regarding use, measurement accuracy, verification, and calibration. If you cannot find the information you are looking for here, please do not hesitate to contact us—we will be happy to provide you with details based on how you use the measuring device. Telefon: +420 771 230 755 E-mail: kalist@kalist.cz