Professional digital thermometer and hygrometer TFA 31.1066.01

Professional digital thermometer and hygrometer TFA 31.1066.01


Product code: TFA31.1066.01 Shipping and Payment
39,26 € excl. VAT (47,50 € incl. VAT)
Specify product selection
No calibration Calibration -20°C/0°C/+20°C Calibration for refrigerators +2°C/+4°C/+8°C Calibration for drug storage 0°C/+15°C/+25°C Calibration at room temperature +10°C/+20°C/+30°C Humidity calibration 50%/60%/70% Temperature and humidity calibration +10°C/+20°C/+30°C, 50%/60%/70% Temperature and humidity calibration - own calibration points Temperature calibration - own 3 calibration points Humidity calibration - own 3 calibration points
usually in stock Watch availability - dispatch usually within 24 hours
TFA
Product code: TFA31.1066.01 Shipping and Payment

The TFA 31.1066.01 is a digital professional thermo-hygrometer for orientation and operational monitoring of temperature and relative humidity. The device design is suitable for manual measurements in the field and indoors, where climate conditions need to be checked quickly without installing a fixed monitoring system.

The device shows the current temperature and humidity on a display with backlight. For work in operational environments, the HOLD function is useful because it allows the currently measured value to remain shown on the display. The MAX/MIN function is used to display the highest and lowest values since the last reset.

The thermometer with hygrometer is suitable for checking the microclimate in warehouses, technical rooms, residential areas, greenhouses, workshops and operations where air temperature and humidity need to be monitored continuously or by spot checks.

Calibration option

If required, we offer accredited calibration of temperature and relative humidity in our own accredited calibration laboratory. A calibration certificate can be issued for the calibration. It serves as proof of measurement traceability and is suitable for operations where the control of measuring instruments must be documented.

Calibration is particularly suitable for companies, laboratories, warehouses, food operations, facility management or other workplaces where measured values are used for environmental monitoring, internal documentation or quality system requirements.

Suitable use

  • Monitoring temperature and relative humidity in warehouses
  • Measuring climate in residential and office spaces
  • Checking conditions in greenhouses
  • Spot checking the environment in workshops and technical rooms
  • Use in facility management for checking indoor climate
  • Checking storage conditions for goods sensitive to temperature and humidity
  • Measurement in industry, trade, craft operations and hobby use

Technical parameters

  • Type of measuring instrument: digital thermo-hygrometer / thermometer with hygrometer
  • Measured quantities: temperature, relative humidity
  • Temperature measuring range: -50 to +70 °C (-58 to +158 °F)
  • Temperature measurement accuracy: ±0.3 °C within the range of -20 to +50 °C, otherwise ±0.5 °C
  • Temperature resolution: 0.1 °C
  • Humidity measuring range: 10 to 99 % RH
  • Humidity measurement accuracy: ±3 % RH within the range of 20 to 80 % RH, otherwise ±4 % RH
  • Humidity resolution: 0.1 % RH
  • Functions: HOLD, MAX/MIN, display backlight, °C/°F switching
  • Material: plastic
  • Degree of protection: not specified by the manufacturer. The device is not intended for permanent use in humid, dusty or outdoor environments without appropriate protection.
  • Power supply: 2× AA 1.5 V batteries
  • Batteries included: no
  • Dimensions: 63 × 34 × 203 mm
  • Weight: 103 g

Delivery contents

Digital thermo-hygrometer TFA 31.1066.01
Instruction manual

Power supply and operation

The device is powered by two AA 1.5 V batteries, which are not included in the package. When the battery symbol appears on the display, the batteries must be replaced. The device should be switched off before replacing the batteries.

The thermo-hygrometer is intended for manual measurement. After inserting the batteries, it is ready for use and displays the current temperature and relative humidity.

Display and controls

The display shows the current temperature and relative humidity. The display also includes MAX/MIN value indicators, the battery symbol and the HOLD function.

The display backlight is activated by pressing any button. The backlight duration can be set to 1, 5, 10 or 15 minutes, with the default setting being 1 minute. The temperature unit can be switched between °C and °F.

Key features

  • Measurement of temperature and relative humidity with one device
  • Temperature measuring range -50 to +70 °C
  • Humidity measuring range 10 to 99 % RH
  • Temperature accuracy ±0.3 °C within the range of -20 to +50 °C
  • HOLD function for retaining the current value on the display
  • MAX/MIN function for displaying the highest and lowest values
  • Backlit display with adjustable backlight duration
  • °C/°F unit switching
Parameters
Meter function MAX / MIN - save the maximum and minimum value HOLD - stabilization of the meter at the current value
Temperature range (max) 70 °C
Temperature range (min) -50 °C
Temperature resolution 0,1 °C
Temperature measurement accuracy ±0,3 °C v rozsahu -20 až +50 °C, jinak ±0,5 °C
Humidity measurement range 10 to 99 %
Humidity measurement accuracy ±3 % RV v rozsahu 20 až 80 % RV, jinak ±4 % RV
power supply 2× baterie AA 1,5 V

FAQ 

What is the TFA 31.1066.01 thermometer with hygrometer used for?
The TFA 31.1066.01 thermometer with hygrometer is used to measure air temperature and relative humidity. It is used for monitoring indoor climate in warehouses, operations, residential areas, greenhouses, workshops or technical rooms.

What is the temperature measuring range?
The temperature measuring range is -50 to +70 °C. The device also allows temperature display in degrees Fahrenheit within the range of -58 to +158 °F.

What is the temperature measurement accuracy?
The temperature measurement accuracy is ±0.3 °C within the range of -20 to +50 °C. Outside this range, the temperature measurement accuracy is ±0.5 °C.

What is the humidity measuring range?
The relative humidity measuring range is 10 to 99 % RH. The device is suitable for routine monitoring of air humidity indoors, in operations, warehouses or greenhouses.

What is the humidity measurement accuracy?
The humidity measurement accuracy is ±3 % RH within the range of 20 to 80 % RH. Outside this range, the humidity measurement accuracy is ±4 % RH.

Does the device have a HOLD function?
Yes, the device has a HOLD function. This function allows the currently measured temperature and humidity values to remain shown on the display.

Can the device display maximum and minimum values?
Yes, the device can display maximum and minimum temperature and humidity values. The MAX/MIN values are displayed from the last reset and can be cleared.

Can the device be calibrated?
Yes, the device can be calibrated for temperature and relative humidity measurement. If required, we offer accredited calibration in our own accredited calibration laboratory and issue a calibration certificate.

Are batteries included in the package?
Batteries are not included in the package. The device requires 2× AA 1.5 V batteries for operation.

Is the TFA 31.1066.01 suitable for professional use?
Yes, the TFA 31.1066.01 is suitable for professional use when checking temperature and humidity in operations, warehouses, facility management, craft activities and industrial environments. For use in quality systems, it is advisable to supplement the device with calibration.

%s ...
%s
%image %title %code %s
%s